INKJET UV Printer & Coat & CUT

INKJET UV Printer & Laser Cutting Machine

경기도 안양시 동안구 시민대로109번길 29, 13층 1302호

Following actions do not work when connecting SW

Following actions do not work when connecting SW ARTJET 2025

Following actions do not work when connecting SW

 

So far,  UV printer-related issues, We’ve compiled

24 articles on ink supply issues,
9 articles on head basics,
12 articles on actual head issues and their solutions.

Related information can be found via the links.

 

 

We’re currently discussing mechanical issues.

1. “I hear a clicking sound on the X-axis.”

I hear a clicking noise on the X-axis
I hear a clicking noise on the X-axis

2. “Bending occurs only in certain areas of the flatbed.”

Banding occurs in certain sections
Banding occurs in certain sections

3. Importance of head height in bidirectional printing

Importance of Head Height in Bidirectional Printing
Importance of Head Height in Bidirectional Printing

4. “What’s the problem with this?”

When Bidirectional offset is completely off
When Bidirectional offset is completely off

5. Symptoms that occur when the wiper height is high during head cleaning

Symptoms when the wiper height is incorrect
Symptoms when the wiper height is incorrect

6. “The cleaning wiper does not move when cleaning the head.”

When the cleaning wiper does not move
When the cleaning wiper does not move

 

Today, I will explain the problem of Software program keeps freezing without performing the following actions when connecting.

 

 

I. Problems and Solutions _Following actions do not work when connecting SW

1. When the program is initialized, the next action cannot be performed. _Following actions do not work when connecting SW

Sometimes, when setting up the printer, the fixing plate below may not be in the correct position, preventing subsequent operation during initialization.

Following actions do not work when connecting SW
Following actions do not work when connecting SW

2. Problem symptoms _Following actions do not work when connecting SW

During software initialization, communication is checked and several actions are performed.

One of these actions is the CAPTOP STATION moving upwards, which must be completed before the next action can begin.

As shown in the photo below, the capping fixing plate (silver bar) is in the wrong position.

Following actions do not work when connecting SW
Following actions do not work when connecting SW

Unable to move up, the device remains stuck in this state, unable to perform the next action.

This causes the device to become unable to perform the next action during software initialization.

You can watch the short video clip at the link below to see the phenomenon that occurs when the problem occurs.

When the capping fixing plate does not fit

 

3. Problem solving _Following actions do not work when connecting SW

You can do this by loosening the capping fixing plate shown in the picture below.

Following actions do not work when connecting SW
Following actions do not work when connecting SW

II. Role of the capping fixation plate _Following actions do not work when connecting SW

1. Two fixed plates _Following actions do not work when connecting SW

When you first bring the equipment into the office, there are two things to do first.

First, remove the head carriage fixing plate, as shown in the picture below.

This fixing plate prevents the head carriage from moving during transport, preventing problems that may arise.

Following actions do not work when connecting SW
Following actions do not work when connecting SW

Second, loosen the capping fixing plate screws described above.

Leaving the capping fixing plate loose isn’t a major issue, but it could cause a jam during the SW initialization described above, preventing the next operation.

The capping station fixing screws are tightened after equipment setup and before transport to the customer site, and then loosened again after transport.

Following actions do not work when connecting SW
Following actions do not work when connecting SW

2. Small but meaningful _Following actions do not work when connecting SW

The capping station fixing plate secures the capping station after capping is complete.

If the capping station plate moves, cleaning and pumping may not function properly.

While this may not be of much use to the users, it’s a crucial feature for us, who have to set up, transport, and reinstall the equipment.

 

III. This is how ARTJET supports our customers.

One thing I feel while selling and maintaining ARTJET UV Printers for 5 years is that the next most important thing after product stability is Troubleshooting DATA.

All products have problems, whether they are actual equipment problems or consumer errors, and product stability is how easily and quickly you solve those problems.

We are organizing all the troubleshooting DATA as follows.

You can see the product print quality by clicking here.

 

Roland UV Printer summary
ARTJET UV Printer

1. Complete Guide to Printhead Problems and Solutions

 

1st Summary

ARTJET UV Printer Problems and Solution _Printhead Problems Summary

Additional issue and solution
The red color does not appear at first, then appears during printing, and then does not appear again
Printhead replacement video and precautions

 

2nd Summary
I have summarized the basic knowledge about the head and the head problems that have occurred as follows.

Complete summary of actual head problems ARTJET 2025

 

2. Complete Guide to Ink Supply Problems and Solutions

Previously sorted, ink supply problem summary

2nd Summary
This is a summary of all the issues that have occurred over the past 5 years. If you have a printer that uses the Damper method, you can solve most problems by just looking at the link below.
If you go to the link, there are a total of 24 problems and solutions.

Complete summary of actual head problems ARTJET 2025

Addition

“no clogged nozzles, but banding in the red ARTJET 2025”
“When I print it, the whole thing has a yellow tint to it”

 

3. Mechanical problem and Solutions 

1. How to align the print head in a straight line
2. There is a clicking noise from the X-axis
3. Banding problem in specific section
4. The Importance of Head Height in Bidirectional Printing
5. Problems that occur when the wiper height is high
6. When the cleaning belt screw is loose
7. When the capping fixing plate does not fit
8. How do I prepare the ARTJET electricity?
9.When Anti-crash becomes a jam in captop
10. Print head Anti crash system 

 

4. Electron board and Software problem is hereunder. 

1. The printer works but printing does not work
2. Resetting to default settings
3. Touch panel does not turn on
4. The printer is printing, but nothing is printed
5. Software closes when I just press the print button
6. Printing in the wrong place
7. Positioning misalignment in X-axis direction
8. How to make the Offset fine tune
9. Vertical offset is not correct only for the right section of white
10. Software turn off when click print button

 

5. Sai Flexi Rip software  

1. How to make the Spot Color & several mistakes
2. Color is strange after applying Spot color
3. White is sticking out
4. Installation and Dongle Key Recognition Failure Measures
5. Dongle Key Recognition Failure
6. White lines appear when printing only color
7. Color Adjustment through Graph
8. Print size compensation
9. Ink Consumption Calculation
10. What is ICC profile & menu board UV Printing
11. Dongle Key recognition Failure from USB port

 

6. Problems and solutions from actual consumer sites

1. Paper that absorbs ink
2. A line-like thing appears at the end of the white print surface
3.Can varnish banding be reduced?
4. Are there many problems with China’s UV Printer?

7. UV Printer Application 

we are explaining not only UV printer problems and solutions, but also what products are produced with UV printers.

1. Braille printing
2. Flip the material and align it
3. 2.5D UV print
4. ARTJET UV Printer Application 6 _아크릴 본딩 장비
5. I phone 14 print limitation 
6. Mask printing not recommend
7. Leather Cigarette Case UV Printing
8. Round soccer strategy board UV printing
9. Primer  performance & limitation 
10. UV Print & Laser crop mark cutting
11. Mobil case UV print profit
12. Screen vs Digital Comparison and UV Printing on Hand Sanitizer Cases
13. Bottle zig & print
14. Canvas UV Printing
15. Applying epoxy effect with varnish
16. Making a light frame with UV Printer & Laser cutter
17. UV Printer & Laser Cutting Equipment Button Name Tag Making
18. UV Printer & Laser Cutting Making a Cell Phone GripTok
19. Making an Acrylic Keychain with UV Printer & Laser Cutter
20. UV Print with Zig
21. How to make RD WORKS CCD camera cutting Video manual
22. Acrylic bonding equipment
23. All the steps to create UVDTF
24. UVDTF TEST Result on various material
25. ARTJET CW+C Print time & Ink Cost
26. Create a white shield with different images on the front and back of the keyring
27. Keyring Business Required Equipment and Investment Costs
29. Acrylic Lighting Goods
30. Ballpoint pen jig printing
31. Staining occurs when printing on coated leather

 

8. Bonus

1. ARTJET UV Printer Old Model Refurbished
2. UV Printer Laser Cutter Bonding Machine Which equipment should I buy first?
3. Considerations when choosing a UV printer
4. DTF Printer Price and Specification Survey
5. Acrylic Bonding Equipment Don’t Put It Off Anymore
6. China inkjet level now
7. Thoughts on KOSIGN 2024
8. ARTJET Delivery Preparation
9. ARTJET Setting Sequence 
10. UV Printer History and Future Prediction 1
11. UV Printer History and Future Prediction 2
12. UV Printer History and Future Prediction 3
13. UV Printer History and Future Prediction 4
14. UV Printer History and Future Prediction 5
15. Are there many problems with China’s UV Printer?
16. UV Printer Small Text Meaning
17. Is the XP600 head okay
18. Roland UV Printer Summary
19. Mimaki UV Printer Summary
20. UV Printer Alibaba Direct Purchase Considerations
21. Things to consider when buying a used UV Printer
22. Bi Uni Print Quality Differences
23. RDworks download install and laser head position by SW

 

That’s it for today.

댓글 달기